Product Overview
Downloads
Current-compensated choke series for lighting applications
Features and Benefits
Increases power factor
Typical Applications
Mains operated LED drivers
Technical Specifications
MTBF
> 13,000,000 hours acc. MIL-HDBK-217
Vibration and shock
3M4 acc. IEC 60721-3-3
Rated currents
0.2 to 2 A @ 65°C
Inductance reduction (DC bias with IN)
Less than 10% at rated current
Cooling
AN - natural convection
Rated inductance
3 to 90 MILLIHENRY
3 to 40 mH common-mode
Stray inductance
0.1 - 3.1 mH
Flammability corresponding to
UL 94 V-0
Operating frequency
DC to 60 Hz
Temperature range (operation and storage)
-40°C to 125°C
Maximum continuous operating voltage
300 VAC, 50/60 Hz
Altitude
Derating above 2,000 m
Climatic class
40/125/56 acc. IEC 60068-1
Creepage and clearance distances
Creepage > 3 mm / Clearance > 2.5 mm between windings
Overvoltage category
II acc. IEC 60664-1
Design corresponding to
IEC 60938-1/-2
Protection category
IP 00
Pollution degree
PD2 acc. IEC 60664-1